AS210/AS211/AS212 Crane Loudspeaker & Controller Kit

AS210/AS211/AS212 Siren and speaker kit is specially designed for tyre crane, gantry crane, and bridge crane used in harbors, metallurgies and coalmines etc. This product features compact size, good appearance, ease of mount and operation. Practical application shows that it plays an important role in guaranteeing safety of human life and equipments.

Specifications

Description Parameter
Applications Used in the cabs of engineering machinery (travelling cranes, crawler cranes, truck cranes and etc.),port machinery(gantry crane, overhead travelling cranes and etc.).
Supply voltage AC110V~265V/DC110V~260V
Frequency 50Hz~60Hz
Standard GB/8108-1999
Tone A、B、E(customized available)
dB 106dB~110dB
Speaker 10W/8Ω 25W/16Ω 50W/16Ω
Power 10W/25Wx1/25Wx2/50W
Output Carrier power 200W
Ambient temperature -30˚C ~ +60˚C
Humidity 10% ~ 95% (non-condensing)
Material  Aluminum alloy
Weight 1.5kg

Functions & Features

  • Speaking prior to alarm.
  • Volume adjustable.
  • Microphone & Loudspeaker available.
  • Various tones to choose from.
  • Visible and audible alarm synchronous (optional).
  • Power off memory, can hold the setting data.
  • Several kinds of combination mode for choose.
  • Nice appearance, convenient opeartion.

Model Selection

Model Installation Tone Loudspeaker Microphone Power
AS210 Flat installation A/B/E/ Speech 10W/8Ω(YH10-2) SE/SS-A 10W
AS211 Flat installation A/B/E/ Speech 25W/16Ω(YH25-3) SE/SS-A 25W×1/25W×2
AS212 Flat installation A/B/E/ Speech 50W/16Ω(YH50-3) SE/SS-A 50W

Accessories products

Installation and operation

  • Mount the device onto mounting surface with M5 (push-in type) or M6 screws (surface mounting), the mounting surface should have enough strength to hold the device.
  • Make sure power supply is matched to the device’s rated voltage, and noted the Polarity, Wiring the device base on “wiring drawing” to connect external devices, and please take notice of negative and positive pole when connect the gooseneck microphone.
  • Power on, the red power indicator lighting, push the key of ′ON/OFF’ the indicator off, and the controller will be the standby mode, push again the controller will be the operation mode.
  • Push the “alarm indicator” switch, the yellow indicator lighting, and the alarm light terminal with AC220V output at the same time. Push again will be off.
  • When push the alarm button, alarm system operation, and at the same time, yellow indicator will lighting, the alarm terminal with AC220V output, loudspeaker will with alarm, push the alarm button again, alarm system and indicator will stop at the same time to obtain the Visible and audible alarm synchronous function.
  • Tone select;push the tone button, the A、B、E tone will be alarm cycles, please choose the tone you want.
  • Volume adjust, through the ∧ and ∨ of Volume to turn up and turn down the volume, if under the alarm condition, push the ∧ and ∨ of Volume to turn up and turn down the alarm volume; Push the microphone switch can be speaking, and constant push can adjust the volume of speaker.
  • Gooseneck microphone connected in the back board terminal, please noticed the negative and positive pole, handheld speaker connected in the frond board MIC, push the speaker switch, or close the gooseneck microphone can be speaking amplifier, at this time can through the volume adjust button to turn up and turn down the volume.

Mounting dimension(unit: mm)& Wiring Connection

Operation panel

Notice

  • The controller of this product is the indoor type.
  • Wiring correct, please avoid overload and Short circuit.
  • Check the supply power whether can match the rated power.
  • Loudspeaker power should with the standard configuration.
  • Temperature increasing when using will happen.
  • Do not open controller box. Any questions please contact us.
  • Please use this device after reading instruction manual.
  • Any questions please contact us.

Production Flow Chart